Search results for "Fiber Optic"
showing 10 items of 193 documents
Phosphorous doping and drawing effects on the Raman spectroscopic properties of O=P bond in silica-based fiber and preform.
2012
International audience; We report an experimental study of the doping and drawing effects on the Raman activities of phosphorus (P)-doped silica-based optical fiber and its related preform. Our data reveal a high sensitivity level in the full width at half maximum value of the 1330 cm−1 (O = P) Raman band to the P-doping level. Its increase with the P doping level does not clash with an increase in the disorder of the O = P surrendering matrix. In addition, we observe that in the central core region of the sample (higher doping level), the drawing process decreases the relative band amplitude. We tentatively suggest that this phenomenon is due to the change in the first derivate of the bond…
Determination of refractive index of submicron-thick films using resonance shift in a four-layer slab waveguide
2017
The measurement of refractive index of very thin films at the order of ten to hundred nanometers is cumbersome and usually requires employing sophisticated techniques such as the spectral ellipsometry. In this paper we describe a simple contact method for measuring the refractive index of thin films. Here we have used the prism-coupling technique for characterizing samples prepared as four-layer slab waveguides. The waveguide resonance condition can be calculated by solving simple analytic transcendental equations for the slab waveguide. Then the captured mode position as a function of cladding thickness is used for probing the refractive index of cladding layer. We used indium-tin-oxide la…
In vivo photoprotection mechanisms observed from leaf spectral absorbance changes showing VIS–NIR slow-induced conformational pigment bed changes
2019
Abstract Regulated heat dissipation under excessive light comprises a complexity of mechanisms, whereby the supramolecular light-harvesting pigment–protein complex (LHC) shifts state from light harvesting towards heat dissipation, quenching the excess of photo-induced excitation energy in a non-photochemical way. Based on whole-leaf spectroscopy measuring upward and downward spectral radiance fluxes, we studied spectrally contiguous (hyperspectral) transient time series of absorbance A(λ,t) and passively induced chlorophyll fluorescence F(λ,t) dynamics of intact leaves in the visible and near-infrared wavelengths (VIS–NIR, 400–800 nm) after sudden strong natural-like illumination exposure. …
Optimisation of refractory coatings realised with cored wire addition using a high-power diode laser
2005
Laser; Cladding; Refractory alloys; Factorial experiments; International audience; The objective or our research was to obtain refractory alloys using the high-power diode laser (HPDL) coating technique. After optimisation using factorial experiments, two different cladding regimes were clearly distinguished. It was also shown that a very narrow transition zone exists between the two regimes, and, inside this zone, clad layers having a satisfactory compromise between the response functions (surface aspect and cavity presence) were obtained. The main objective of our study, namely, the control of the operating parameters (geometrical and kinematical) to realise adequate coatings, without cav…
Q-switching of an all-fiber ring laser based on in-fiber acousto-optic bandpass modulator2017
2017
Active Q-switching of an all-fiber ring laser utilizing a novel in-fiber acousto-optic tunable bandpass filter (AOTBF) is reported. The transmission characteristics of the AOTBF are controlled by amplitude modulation of the acoustic wave; the device exhibits a 3-dB power insertion loss, 0.91-nm optical bandwidth, and 28-dB nonresonant light suppression. Cavity loss modulation is achieved by full acousto-optic mode re-coupling cycle induced by traveling flexural acoustic waves. When the acoustical signal is switched on, cavity losses are reduced, and then, laser emission is generated. In addition, by varying the acoustic wave frequency, a wide wavelength tuning range of 30.7 nm is achieved f…
Comparison of two different techniques of fibreoptic intubation
2009
BACKGROUND AND OBJECTIVE The application of analgesics and sedatives during fibreoptic intubation (FOI) may result in a transient decrease in arterial oxygen saturation.This study evaluates two different techniques of FOI and respective effects on procedural duration, arterial oxygen saturation, and coughing by the patient. METHODS Thirty-four patients received a standardized conscious sedation with fentanyl (1.5 microg kg(-1)) and midazolam (12.5 microg kg(-1)).All patients were randomly allocated to one of the following techniques: the 'vaporization' (VAP) technique included four applications of 2 ml lidocaine 2% administered through the working channel of the fibrescope supplying an oxyg…
In vivo ultrasound real-time motion of the cervical spine during intubation under manual in-line stabilization: a comparison of intubation methods
2007
Background and objectiveIn emergency trauma situations, manual in-line stabilization of the cervical spine is recommended to reduce cervical spine movement during intubation. The aim of this study was to compare the effect of manual in-line stabilization during different intubation techniques on three-dimensional cervical spine movements and times to intubation.MethodsForty-eight subjects without any history of trauma, inflammatory or degenerative disorder of the cervical spine were randomly grouped, regardless of gender or age. All underwent elective surgery under general anaesthesia. Under manual in-line stabilization, laryngeal intubation with Macintosh laryngoscope, intubating laryngeal…
Intraoperative monitoring of cerebral microcirculation and oxygenation--a feasibility study using a novel photo-spectrometric laser-Doppler flowmetry.
2009
The present study assesses the utility of a novel invasive device (O2C-, oxygen-to-see-device) for intraoperative measurement of the cerebral microcirculation. CO2 vasoreactivity during 2 different propofol concentrations was used to investigate changes of capillary venous cerebral blood flow (rvCBF), oxygen saturation (srvO2), and hemoglobin concentration (rvHb) during craniotomy.Thirty-four patients were randomly assigned to a low propofol (4 mg/kg/h) versus a high propofol (6 mg/kg/h) group. A fiberoptic probe was applied on the cortex next to the surgical site. Measurements were performed during lower (35 mm Hg) and higher (45 mm Hg) levels of partial pressure of carbon dioxide (paCO2).…
How long should patients refrain from oral food and fluid intake after general anaesthesia? An assessment of the swallowing reflex of postoperative n…
2005
Objective Our aim was to detect swallowing abnormalities in patients after short-term neurosurgical interventions under general anaesthesia, comparing patients with supratentorial operations with a group undergoing extracranial neurosurgery (nucleotomy). Methods 20 patients in each group were examined by fiberoptic endoscopic evaluation of swallowing (FEES) after general anaesthesia. Results No patient demonstrated dysphagia, aspiration, or oxygen desaturation. Conclusion In these patient groups, early postoperative feeding was safe. Postoperative food intake can probably be allowed early after general anaesthesia.
In vivo muscle mechanics during locomotion depend on movement amplitude and contraction intensity
2001
The effects of movement amplitude and contraction intensity on triceps surae and quadriceps femoris muscle function were studied during repetitive hopping. In vivo forces from Achilles and patellar tendons were recorded with the optic fibre technique from eight volunteers. The performances were filmed (200 Hz) to determine changes in muscle-tendon unit length and velocity. When hopping with a small amplitude (23 degrees knee flexion during the ground contact phase), the Achilles tendon was primarily loaded whereas patellar tendon forces were greater in large-amplitude hopping (56 degrees knee flexion). In spite of the different magnitudes of stretch in the quadriceps femoris muscle, the str…